The biodistribution data showed the high selectivity of [I-124] Y-BP in HT1376 human bladder cancer
xenograft models with a tumor-to-muscle ratio of 6.2. This tumor targeting was not observed in control B16F10 melanoma tumor models. In microPET studies, while the control scrambled peptide, [I-124]Y-sBP, did not accumulate in either OICR-9429 research buy the bladder cancer or melanoma, [I-124] Y-BP showed high tumor uptake only in animals with HT1376 bladder cancer cells. Furthermore, [I-124] Y-BP showed superior bladder cancer uptake even compared to most commonly used cancer imaging tracer, [F-18]FDG. The experimental results suggest the potential of [I-124] Y-BP as a new radiopharmaceutical for the non-invasive diagnosis of bladder cancer with high binding affinity and selectivity. (C) 2012 Elsevier Ltd. All rights reserved.”
“center dot Knowing the position of our limbs is critical for accurate
movement. Central motor command signals generated by the brain contribute see more to position sense at the human wrist, but this could not be demonstrated at the elbow.\n\ncenter dot We tested whether this represents a fundamental difference between the two joints or whether it reflects the two different methods used to measure position sense.\n\nRecent studies have suggested that centrally generated motor commands contribute to the perception of position and movement at the wrist, but not at the elbow. Because the wrist and elbow experiments used different methods, this study was designed to resolve the discrepancy. Two methods were used to test both the elbow and wrist (20 subjects each). For the wrist, subjects sat with their right arm strapped to a device that restricted movement to the wrist. Before each test, voluntary contraction of wrist flexor or extensor muscles controlled for muscle spindle thixotropy. After
relaxation, the wrist was moved to a test angle. Position was indicated either with a pointer, or by matching with the contralateral wrist, under two conditions: when the reference wrist was relaxed or when its muscles GSK621 datasheet were contracted isometrically (30% maximum). The elbow experiment used the same design to measure position sense in the passive elbow and with elbow muscles contracting (30% maximum). At the wrist when using a pointer, muscle contraction altered significantly the perceived wrist angle in the direction of contraction by 7 deg [3 deg, 12 deg] (mean [95% confidence interval]) with a flexor contraction and 8 deg [4 deg, 12 deg] with an extensor contraction. Similarly, in the wrist matching task, there was a change of 13 deg [9 deg, 16 deg] with a flexor contraction and 4 deg [1 deg, 8 deg] with an extensor contraction. In contrast, contraction of elbow flexors or extensors did not alter significantly the perceived position of the elbow, compared with rest.